{"product_id":"silent-knight-sk-pull-da-addressable-dual-action-pull-station","title":"Silent Knight SK-PULL-DA Addressable Dual Action Pull Station","description":"\u003cp data-pm-slice=\"1 3 []\"\u003e\u003cspan\u003eThe SK-PULL-DA Intelligent Addressable Dual-Action Manual Fire Alarm Pull Station is designed to provide dependable manual fire alarm activation in compatible addressable fire alarm systems. Featuring a two-step activation mechanism, this pull station helps minimize accidental operation while allowing occupants to initiate a fire alarm quickly during an emergency.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for commercial, institutional, and professional fire protection applications, the SK-PULL-DA communicates with compatible fire alarm control panels through an individually assigned device address. This addressable configuration allows the control panel to identify the specific pull station activated, helping personnel determine the alarm location.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe dual-action operating mechanism requires two separate motions to activate the alarm. Its straightforward design supports reliable manual operation while providing additional protection against unintended activation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor installation and maintenance convenience, the pull station features rotary address switches that allow technicians to configure the device address efficiently. A key-operated test and reset lock supports authorized servicing, while the station can be opened by an installer without triggering an alarm condition when the proper procedure is followed.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eConstructed using durable Lexan polycarbonate materials, the SK-PULL-DA is designed for dependable performance in commercial building environments. Braille text on the station handle supports accessible identification and operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOperating within a specified 15–32V DC input range, this intelligent manual pull station integrates with compatible addressable fire alarm control panels for centralized monitoring and alarm reporting.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e10 Key Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003col data-spread=\"false\" start=\"1\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDual-Action Activation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Requires two separate motions to initiate a manual fire alarm, helping reduce accidental activation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eIntelligent Addressable Operation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides individual device identification through compatible fire alarm control panels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePrecise Alarm Location Identification:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Allows the control panel to identify the address of the activated pull station.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRotary Address Switches:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Enables convenient device address configuration during installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eKey-Operated Reset:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Features a key-operated lock for authorized testing and resetting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eAlarm-Free Maintenance Access:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed to allow authorized installers to open the station without automatically initiating an alarm condition.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eBraille-Identified Handle:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Includes Braille text to support accessible identification.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDurable Polycarbonate Construction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Uses Lexan\/polycarbonate materials for reliable everyday operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e15–32V DC Operating Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed for integration with compatible addressable fire alarm systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eUL-Listed Design:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Identified by the supplied product information as UL listed for fire alarm applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Silent Knight by Honeywell","offers":[{"title":"Default Title","offer_id":68458340843741,"sku":"kaybee-SK-PULL-DA","price":276.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/9912\/2909\/files\/SK-PULL-DA-1.jpg?v=1793974560","url":"https:\/\/kaybeesecurity.com\/products\/silent-knight-sk-pull-da-addressable-dual-action-pull-station","provider":"Kaybee Security","version":"1.0","type":"link"}